Diagnostic Load Tests of a Reinforced Concrete Pan-Girder Bridge
1998
This thesis presents the results from a diagnostic load test performed on a reinforced concrete pan-girder bridge located in Buda, Texas. A total of 45 strain gages and 5 displacement gages were attached to the bridge to measure the response. The results indicate the following: (a) the nonstructural curbs act integrally with the exterior girders and carry a large portion of the load, (b) the maximum positive moments in the bridge are similar to the maximum positive moments obtained from a line-girder analysis of a continuous beam, (c) the AASHTO load distribution factor is unconservative for girders with curbs and conservative for interior girders, and (d) rotational restraint was observed at both supports.
The free Adobe Acrobat Reader can be used to view PDF files.